This page provides information in regards to the RS422 and RS485 standards.
Logic 1 = (Non-inverting - Inverting) > 200mV
Logic 0 = (Non-inverting - Inverting) < 200mV
Image taken from http://en.wikipedia.org/wiki/RS-485
The idle state of RS422 & RS485 is logic 1.
Image taken from http://www.maxim-ic.com/app-notes/index.mvp/id/1833
There are no standards for connector pinouts for RS422 or RS485.
RS-485 and RS-422 Standards | ||
Standard | RS-422 | RS-485 |
Mode of operation | Differential Unidirectional, Multipoint | Differential Full Duplex, Multipoint |
Allowed no. of Tx and Rx | 1 Tx, 10 Rx | 32 Tx, 32 Rx |
Maximum cable length | 4000ft length | 4000ft length |
Maximum data rate | 10Mbps | 10Mbps |
Minimum driver output range | ±2V | ±1.5V |
Maximum driver output range | ±5V | ±5V |
Maximum driver short-circuit current | 150mA | 250mA |
Tx load impedance | 100Ω | 54Ω |
Rx input sensitivity | ±200mV | ±200mV |
Maximum Rx input resistance | 4kΩ | 12kΩ |
Rx input voltage range | ±7V | -7V to +12V |
Rx logic high | >200mV | >200mV |
Rx logic low | <200mV | <200mV |
Table taken from http://www.maxim-ic.com/app-notes/index.mvp/id/736
http://en.wikipedia.org/wiki/RS-422
http://en.wikipedia.org/wiki/RS-485
http://www.maxim-ic.com/app-notes/index.mvp/id/736
http://www.maxim-ic.com/app-notes/index.mvp/id/1833